롤러전압 콘크리트포장의 적정 다짐실험 방안 고찰
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국도로학회
ㆍ수록지정보 : 한국도로학회논문집 / 17권 / 3호
ㆍ저자명 : 정건우, 이승우
ㆍ저자명 : 정건우, 이승우
영어 초록
PURPOSES: To ensure appropriate RCC properties with sufficient strength development and workability, it is necessary to secure a proper level of consistency. It is also necessary to secure maximum dry density, which is an important factor for increasing the interaction of aggregate interlocking, leading to an augmentation of RCC strength. On the other hand, the dry density of RCC can be changed owing to the compaction conditions, water content, and particle size distribution. A Proctor test and a modified Proctor test were used for determining the optimum water content needed to achieve maximum dry density with different amounts of compaction energy. A Vebe test, on the other hand, was used for checking the level of consistency, which is important for producing a workable mixture.METHODS : To confirm the degree of compaction at various particle sizes, RCC mixtures with different sand/aggregate ratios were evaluated. The Proctor test and modified Proctor test were applied to these mixtures to check the effect of the aggregate gradation and compaction energy on the maximum dry density and optimum water content. During each test, three specimens were produced for all types of water content under each aggregate gradation. A compaction curve and the optimum water content and maximum dry density for each aggregate gradation were then obtained for both tests. The range of water content for the appropriate consistency of each aggregate gradation was determined through a Vebe test. The optimum water content was then evaluated based on this range.
RESULTS : The compaction test results show that the modified Proctor test provides a higher maximum dry density and lower optimum water content compared with the standard Proctor test. For the modified Proctor test, two cases of aggregate gradation (s/a = 30% and 70%) had the optimum water contents outside of the appropriate water content range. For the standard Proctor test, on the other hand, none of aggregate gradations provided the optimum water content within the desired range.
CONCLUSIONS : The modified Proctor test should be used for an RCC mixture design because it can provide adequacy between maximum dry density and consistency. Moreover, the compaction roller has become highly developed for higher compaction energy.
참고 자료
없음태그
"한국도로학회논문집"의 다른 논문
- 회전교차로 도입에 따른 교통안전성 향상 효과분석9페이지
- 차량 가속특성에 따른 이산화탄소(CO2) 배출량 비교8페이지
- 구조방정식을 이용한 고령운전자 교통사고 인적 피해 심각도 분석 (고양시를 중심으로)8페이지
- 지방부 신호교차로 주.야간 교통사고 예측모형 개발 및 비교 분석9페이지
- 고속도로 교통수요모형 구축을 위한 유전자 알고리즘 기반 TCS 차종별 최적 승용차환산계수 산정9페이지
- 접착식 콘크리트 덧씌우기를 위한 초속경화 첨가재 현장 혼합 폴리머 개질 콘크리트의 적용성 연구11페이지
- 유한요소해석을 통한 섬유보강 아스팔트의 파괴거동특성 분석7페이지
- 일반국도 현장조사 모니터링을 통한 장수명 아스팔트 덧씌우기 포장의 공용성 분석8페이지
- 도로의 야간 교통사고 저감을 위한 야광형 포장노면표시 기술개발의 적용성 연구10페이지
- 골재 입도분포가 도로포장용 롤러전압 콘크리트에 미치는 영향 연구10페이지