구조용단열패널의 정적가력과 반복가력 성능 평가
(주)코리아스칼라
- 최초 등록일
- 2016.05.03
- 최종 저작일
- 2013.03
- 7페이지/
어도비 PDF
- 가격 4,000원
![할인쿠폰받기](/images/v4/document/ico_det_coupon.gif)
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국복합신소재구조학회
ㆍ수록지정보 : 복합신소재구조학회 논문집 / 4권 / 1호
ㆍ저자명 : 나환선, 이현주, 최성모
목차
1. 서 론
2. 시험계획
3. 정적가력과 반복가력 시험결과 분석
4. 결 론
References
영어 초록
Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. In Korea, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to identify fundamental performance of both monotonic load and quasi static cyclic load for SIPs in shear wall application. Static test results showed that maximum load was 44.3kN, allowable shear load was 6.1kN/m, shear stiffness was 1.23 M N/m, and ductility ratio was 3.6. Cyclic test was conducted by two kinds of specimens : single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, it was recommended that the allowable shear load for panels was at least 6.1kN/m.