다단 나노여과 공정에서 고농도 geosmin 및 2-Methylisoborneol (MIB)의 제거특성
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 대한상하수도학회
ㆍ수록지정보 : 상하수도학회지 / 28권 / 4호
ㆍ저자명 : 유영범, 최양훈, 김동진, 권순범, 김충환
ㆍ저자명 : 유영범, 최양훈, 김동진, 권순범, 김충환
영어 초록
Algal problem in drinking water treatment is being gradually increased by causing deterioration of water supplies therefore, especially taste and odor compounds such as geosmin and 2-MIB occur mainly aesthetic problem by its unpleasant effects resulting in the subsequent onset of complaints from drinking water consumer. Recently, geosmin and 2-MIB are detected frequently at abnormally high concentration level. However, conventional water treatment without advanced water treatment processes such as adsorption and oxidation process, cannot remove these two compounds efficiently. Moreover, it is known that the advanced treatment processes i.e. adsorption and oxidation have also several limits to the removal of geosmin and 2-MIB. Therefore, the purpose of this study was not only to evaluate full scale nanofiltration membrane system with 300 m3/ day of permeate capacity and 90% of recovery on the removal of geosmin and 2-MIB in spiked natural raw water sources at high feed concentration with a range of approximately 500 to 2,500 ng/L, but also to observe rejection property of the compounds within multi stage NF membrane system. Rejection rate of geosmin and 2-MIB by NF membrane process was 96% that is 4% of passage regardless of the feed water concentration which indicates NF membrane system with an operational values suggested in this research can be employed in drinking water treatment plant to control geosmin and 2-MIB of high concentration. But, according to results of regression analysis in this study it is recommended that feed water concentration of geosmin and 2-MIB would not exceed 220 and 300 ng/L respectively which is not to be perceived in drinking tap water. Also it suggests that the removal rate might be depended on an operating conditions such as feed water characteristics and membrane flux. When each stage of NF membrane system was evaluated relatively higher removal rate was observed at the conditions that is lower flux, higher DOC and TDS, i.e., 2nd stage NF membrane systems, possibly due to an interaction mechanisms between compounds and cake layer on the membrane surfaces.참고 자료
없음"상하수도학회지"의 다른 논문
수돗물 음용 및 인식 분석방법에 대한 고찰 : 서울 수돗물 아리수에 대한 설문 결과12페이지
세라믹막(MF) 고도정수처리에서 NOM 제거 특성10페이지
막여과 정수장 배출수처리시설의 효율적인 운영방안11페이지
하수고도처리용 미세조류의 최적회수를 위한 전기응집기술 적용에 있어 전류의 영향6페이지
PVC 하수맨홀의 구조적 거동 및 예측10페이지
초순수 제조 공정에서 역삼투 막의 저농도 유기물 제거6페이지
앙상블 모형을 이용한 단기 용수사용량 예측의 적용성 평가13페이지
단일벽 탄소나노튜브의 미량유해물질 흡착거동에서 양이온 계면활성제의 영향에 관한 연구11페이지
무기슬러지 분리와 슬러지 가용화를 적용한 고효율 호기성 소화기술(CaviTec II)에 의한 슬러지..7페이지
CFD에 의한 수직형 정수처리 실증시설 내 압력식 오존접촉조 성능개선에 관한 연구10페이지